Komatsu — Komatsu K EAM04 9 700 T Operation and Maintenance Manual for Bulldozers

OPERATION OPERATION STOPPING ENGINE 3 NOTICE If the engine is abruptly stopped before it has cooled down, engine life may be drastically shortened. Do not abruptly stop the engine except for an emergency. If the engine has overheated, do not stop it abruptly, run it at medium speed allowing the engine to gradually cool down, then stop it. 1. Lower the work equipment to the ground. 2. Place fuel control dial (1) in the low idle (MIN) position and run the engine at low idle speed for about 5 minutes to allow it to gradually cool down. 3. Turn the key in ignition switch (2) to the OFF position (A).

The engine will stop REMARK When the key in starting switch (2) is turned to the OFF posi- tion, the engine stops, but the machine power supply is not cut immediately. The power supply is maintained for several seconds to enable the controller to save the operating condition to memory and shuts down the system after that. The length of time that the power supply is maintained depends on the operating condi- tion. Even when the cooling fan is being operated in reverse or in the cleaning mode, the machine power supply is not cut imme- diately when the key in starting switch (2) is turned to the OFF position. The power supply is maintained for seven seconds to protect the hydraulic circuit.

During that time, the fan operation confir- mation lamp on the monitor panel flashes. 4. Remove the key from starting switch (2). 3-97