OPERATION TRANSPORTATION 2. Remove the quick coupler (1), then remove the work equipment assembly. 3. Remove the left and right trunnions (2). (For D61PX) REMARK In the case of D61PX, remove the left and right trunnions (2). In the case of D61EX, the width including the left and right trun- nions (2) is within 3.0 m (9 ft 10 in), so there is no need to remove them. 4. Tie the tilt hose with a band to prevent it from being dam- aged. PRECAUTIONS WHEN REMOVING ROPS 3 When removing ROPS for transporting the machine, do as follows: NOTICE ROPS is an important safety component. Be sure to tighten mounting bolts (1) securely to the specified torque when installing. Tightening torque:
785 to 980 N·m (80 to 100 kgf·m, 578.6 to 723.3 lbft) 1. Loosen bolts (1) and remove ROPS. 3-119