Komatsu — Komatsu K EAM04 9 700 T Operation and Maintenance Manual for Bulldozers

OPERATION TROUBLESHOOTING PUMP TEST If the operation is carried out without inspecting the hydraulic pump, it may lead to damage of the brake system seal. Always inspect the hydraulic pump before connecting it. 1. Install tee (1) to the discharge portion of the pump, then install oil pressure gauge (2) and accumlator (3), rubber hose (4). Install quick coupler (5) to the end of rubber hose (6) that is mounted to the machine. 2. Pump handle (6) and check that the pressure gauge becomes 2.7 to 3.1 MPa (28 to 32 kg/cm2, 298 to 454 PSI). 3-135 CAUTION