Komatsu — Komatsu K EAM04 9 700 T Operation and Maintenance Manual for Bulldozers

EXPLANATION OF COMPONENTS OPERATION FAN ROTATION SELECTOR SWITCH This switch (6) is used to switch the direction of rotation of the cooling fan. position : Normal rotation Normally use this position. The air is pushed out to the front through the radiator mask. The speed of the fan changes to match the temperature of the coolant in order to improve the cooling efficiency. REV position: Reverse rotation The fan rotates in the reverse direction. The air is sucked into the engine room through the radiator mask. This makes it possible to use the heat from the radiator to warm the operator's cab.

Operating with the fan rotating in reverse may cause overheat- ing, so use this function only during cold weather (ambient tem- perature below 15°C). CLN position: Cleaning The fan rotates in the reverse direction at high speed, regard- less of the coolant temperature. Use this function to clean the radiator fins. Stop the engine and turn the starting switch to the ON position before operating this switch. REMARK If the engine is running, the direction of rotation of the fan will not change even when the fan rotation selector switch is oper- ated. The fan operation confirmation lamp will flash to inform the operator that the direction of rotation of the fan has not changed.

Stop the engine, then start it again. The direction of rotation of the fan will be switched. When the cooling fan is being operated in reverse or in the cleaning mode, even if the starting switch is turned to the OFF position, the hydraulic circuit protection function will be actu- ated and the power supply will not be cut immediately. During this time, the fan operation confirmation lamp will flash to inform the operator that the power supply is being main- tained. 3-22