Deutz — 3.3.2 Operating Data

© 0885 Specification Data Section: 3.3 Page: 3-1-05 Engine: S/BV 6/8/9 M 628 6-cyl. 8-cyl. 9-cyl. Drain A or B 10° 8% 7° Connection for inclinations α ± 8° - 10° > 7° - 10° for inclinations α ± Oil Delivery Rate for Valve Seat Lubrication Rated Engine Speed Delivery in drops / 4 min 1/min. 6-cyl. 8-cyl. 9-cyl. 1000 42 56 63 900 37 50 56 800 34 45 50 750 32 42 47 720 30 40 45 Admissible deviation ± 4 gocce/4 min 09 Cooling Water System Water quality see Section 6 Engine system capacity 6-cyl.: 225 litres 8-cyl.: 275 litres 9-cyl.: 300 litres Max.

coolant temperature at engine outlet during full-load operation (In case of 2-stage charge air cooler, measured at cooler inlet) - with single-circuit cooling system 80°C - with two- and three-circuit cooling system 85°C Temperature difference between full load and idling operation (at engine outlet) 8 - 12 °C Temperature difference between cooling water at engine inlet and engine outlet under full load conditions 8 - 12 °C (In case of 2-stage charge air cooler, measured at cooler inlet) Cooling water preheating temperature - for standby duty 50 °C - for engines starting with blended fuel - viscosity 180 mm2/s at 50°C (cSt) 70 °C - viscosity > 380 mm2/s at 50°C (cSt) 80 °C - for all other engines 25 °C Max.

coolant temperature at charge air cooler inlet 50 °C Max. coolant temperature at built-on oil cooler inlet 45 °C Max. raw water temperature at heat exchanger inlet 32 °C Max. coolant pressure at engine inlet with built-on or separate pump ~ 4 bar Coolant temperature at injection nozzle inlet approx. 85°C Min. pressure of separate injection nozzle coolant pump 3 bar Drain A or B Connection for inclinations α ± 6-cyl. 8-cyl. 9-cyl. 10° 8% 7° > 8° - 10° > 7° - 10° Rated Engine Speed Delivery in drops / 4 min 1/min. 6-cyl. 8-cyl. 9-cyl. 1000 900 800 750 720 42 37 34 32 30 56 50 45 42 40 63 56 50 47 45 Admissible deviation ± 4 gocce/4 min