Deutz — 05.04.14 Woodward UG8D/UG8L Hydraulic Governor Linkage Setting, S/BV 9 M 628

© 0595 Woodward UG8D/UG8L Hydraulic Governor Linkage Setting Job Card No.: 05.04.14 Page 11 of 12 Engine: S/BV 9 M 628 Filing No.: 0178-29-10 1809 12. Set stop screw A13 so that load indicator on injection pump (Fig. 18) points to graduation 14. © 24 938 1 Fig. 18 13. Check that linkage abuts at top screw (*) - Fig. 19 - when pushed to maximum load (point A13). Upon completion of the setting, lead-seal the engine output (**). © 24 939 1 Fig. 19 14. After the engine has been put back to service and final load setting has been made, check that governor scale gives the following rea- dings:

No load = graduation 2 Full load = graduation 8 Failing this, adjust linkage (points C8 or C10 under 11.). © 24 938 1 © 24 938 1 © 24 939 1 © 24 939 1