Komatsu — SAFETY-SUCTION VALVE

STRUCTURE AND FUNCTION, MAINTENANCE STANDARD SAFETY-SUCTION VALVE 2) When HST pump discharge amount is being dis- charged from port PA i) Valve at piston pump discharge side If pressure oil is being discharged from port PA of HST pump (4), port PA becomes the high- pressure side. This pressure oil at port PA passes through pas- sage b in the body and flows into port D . When this happens, sleeve (3C) is pushed fully to the left because of the relationship of the dif- ference in area ( A1 > A2 ). Therefore, the pressure oil from charge pump (1) is prevented from flowing in. 3. Valve at piston pump suction side Operation Port PB becomes the suction side, so it is at low-pressure.

Sleeve (3C) is pushed to the right by the charge pressure oil from the relationship of the difference in area ( A1 A2 ), and the seat of sleeve (3C) opens. As a result, the charge pressure oil at port B passes through this gap, flows to port PB , and carries out the charge action in the HST circuit. 10-24 D31/37EX, PX-21