Komatsu — CUT-OFF VALVE

STRUCTURE AND FUNCTION, MAINTENANCE STANDARD CUT-OFF VALVE CUT-OFF VALVE 1. HST pump 2. Charge pump 3. Cut-off valve 3A. Spool 3B. Sleeve 3C. Seat 3D. Spring 3E. Adjustment screw 3F. Locknut Function The cut-off valve is installed to the HST pump. When the inside of the HST circuit reaches the maximum pressure, it limits the basic pressure of the HST pump PPC valve, reduces the swash plate angle of the HST pump, and limits the maximum pressure. Operation Port A is connected to the HST circuit, port B is connected to the travel PPC basic circuit, and port C is connected to the HST pump drain. The pressure oil at chamber B is sealed by spool (3A) and sleeve (3B).

The HST circuit pressure becomes high and is a force equivalent to the difference in the cross- sectional area of spool (3A) with the oil pressure at port A . But if it reaches the force set by spring (3D), spool (3A) is pushed to the right. The oil in chamber B flows to port C , so the pressure in chamber B goes down. When the pressure in chamber B goes down, the swash plate angle of the HST pump becomes smaller, and the rise in pressure in the HST circuit is suppressed. D31/37EX, PX-21 10-25