SERVICE PROCEDURE MAINTENANCE CLEAN ELEMENT IN AIR CONDITIONER FRESH AIR FILTER 0. If compressed air is used, there is danger that dirt may fly and cause personal injury. Always wear safety glasses, dust mask, and other protective equipment. If the air conditioner has been used, the air filter should be cleaned. Stop the air conditioner before cleaning the element. 1. Push handle (1) and open cover (2). 2. Remove element (3) and clean it. 3. Direct dry compressed air (less than 0.69 MPa (7 kgf/ cm 2 , 99.4 PSI)) to the element from inside along its folds, then direct it from outside along its folds and again from inside. 4-40 WARNING