Yanmar — 9.6.5 Testing the thermostat

9. Cooling water system 9.6 Thermostat 9.6.1 Functioning of thermostat The thermostat opens and closes a valve according to changes in the temperature of the fresh water inside the engine, controlling the volume of water flowing to the heat exchanger from the cylinder head, and in turn maintaining the temperature of the fresh water in the engine at a constant level. The thermostat is bottom bypass type. It is located in a position connected with the cylinder head outlet line at the top of the top of fresh water pump unit.

When the fresh water temperature exceeds the above temperature, the thermostat opens, and a portion of the water is sent to the heat exchanger and cooled by seawater, the other portion going from the bypass line to the fresh water pump intake. The bypass line is closed off as the thermostat valve opens and is completely closed when the fresh water temperature reaches 81.5 ° C (valve lifts 4 mm (0.1575 in)), sending all of the water to the heat exchanger. 9.6.2 Thermostat construction The thermostat used in this engine is of the wax pellet type, with a solid wax pellet located in a small chamber. When the temperature of the cooling water rises, the wax melts and increases in volume.

This expansion and construction is used to open and close the valve. Thermostat cover 9.6.3 Characteristics of thermostat Thermostat Fresh water pump body 9.6.4 Thermostat inspection Remove the thermostat cover on top of the fresh water pump and take out the thermostat. Clean off scale and rust and inspect, and replace if the characteristics (performance) have changed, or if the spring is broken, deformed ar corroded. 9.6.5 Testing the thermostat Refer to 2.5 in chapter 2. 169 Opening temperature 69.5-72.5°C Full open temperature 85°C Valve lift at full open 8 mm or more