2. Inspection and adjustment 3) Heat exchanger body water leakage test a) Compressed air/water tank test Fit rubber covers on the fresh water and seawater inlets and outlets. Place the heat exchanger in a water tank, feed in compressed air from the overflow pipe and check for any (water) leakage, (air bubbles). Pressure gauge Air hose Filler cap Rubber cap Test tank Rubber cap Heat exchanger b) Use of the tester Fit the fresh and seawater inlets and outlets with rubber covers and fill the fresh water tank with fresh water. Fit a pressure cap tester in place of the pressure cap, operate the pump for one minute and set the pressure at 0.15 Mpa (1.5 kgf/cm 2 , 21.33 lb/in. 2 ).
If there are any leaks the pressure will not rise. If there are no leaks the pressure will not fall. Pressure tester Pressure gauge Rubber cap Rubber cap 4) Pressure cap inspection Do not open the pressure cap while the engine is running or right after stopping because high temperature steam will be blown out. Remove the cap only after the water cools down. a) Remove scale and rust and check the seat and seat valve, etc. for scratches or wear. Check the spring for corrosion or settling. Replace if necessary. [NOTE] Clean the pressure cap with fresh water as it will not close completely if it is dirty. b) Fit the adopter on the tester to the pressure cap.
Pump until the pressure gauge is within the specified pressure range 0.074-0.103 MPa (0.75-1.05 kgf/cm 2 ) and note the gauge reading. The cap is normal if the pressure holds for six seconds. If the pressure does not rise, or drop immediately, inspect the cap and repair or replace as necessary. Tester Pressure cap 42 Test pressure 0.20 MPa (2 kgf/cm2)