2. Inspection and adjustment 2.3 Adjusting the no-load maximum or minimum speed 2.4 Sensor Inspection 2.4.1 Oil pressure switch Disconnect the connector from the oil pressure switch. Keep the voltameter probes in contact with the switch terminal and cylinder block while operating the engine. It is abnormal if circuit is closed. Oil pressure switch Cylinder block (flywheel side) Tester probes (Continuity test) 2.4.2 Thermo switch Place the thermo switch in a container filled with antifreeze or oil. Heat it while measuring the fluid temperature. The switch is normal if the voltameter shows continuity when the fluid temperature is 93-97 deg C.
Thermometer Tester probes Thermo switch Hot water 44 1) After warming the engine up, gradually raise the speed and set it at the no-load maximum speed. 2) If the no-load maximum speed is out of the standard, adjust it by turning the high idle limiting bolt. 3) Then set the no-load minimum speed by adjusting the low idle limiting bolt. Standards (Unit : min-1 ) No-load maximum No-load minimum 3850±25 850±25 Remote High speed control limiting bolt Fuel cable injection pump Low speed Clamp limiting bolt Control lever Cable joint No-load maximum No-load minimum 3850±25 850±25