Maintenance - Section 42 OM4204 Page 42-4 Automatic Lubrication System GENERAL INFORMATION System Priming The system must be full of grease and free of air pockets to function properly. After maintenance, if the primary or secondary lubrication lines were replaced, it will be necessary to prime the system to eject all entrapped air. To operate the air pump when priming the lube system, use the manual lubrication switch (2, Figure 42-6) located on the instrument panel in the cab. Lubricant Required for System Refer to Lubrication Chart, Section 40, for lubricant specification and for specific lube points. ‰ Above 0°C (32°F) - Use No. 2 Molydisulphide Lubricant.

‰ -32° to 0°F (-25° to 32°F) - Use No. 1 Molydisulphide Lubricant. 1. Fill lube reservoir with lubricant, if necessary. ‰ -54° to -32°C (-65° to -25°F) - Use No. 0 Molydisulphide Lubricant. 2. Remove plugs from all injector manifold dead ends and supply lines. Air Pressure Regulator ‰ Normal Operation - regulator output should be set at 4.2 to 4.6 kg/cm 2 (60-65 psi). 3. Turn air pump vent plug counterclockwise one full turn. To expel trapped air between air pump and supply line connection, run air motor until grease flows freely from the vent plug. Close vent plug clockwise. ‰ Extreme Winter Conditions - regulator output may be reset to 6.3 kg/cm 2 (90 psi). 4.

Continue to run air pump until grease flows from any one plug opening in the system. Replace plug in this opening. Initial Reservoir Fill 1. Remove pipe plug (12, Figure 42-1) from upper portion of lubricant reservoir. This will prevent damage to reservoir by allowing air to escape as reservoir is being filled. 5. Repeat step 4 until all lines are full and all plugs replaced. 2. Clean grease coupler (13) on lower portion of reservoir. NOTE: Fill each feed line with grease before connecting lines to the injector outlets and bearings. This will prevent having to cycle the individual injectors once for each 1.0 in. (25 mm) length of feed line between the injector and bearing fitting. 3.

Attach supply hose from external fill source to coupler (14). 4. Fill reservoir with approximately 60 lbs. (27.24 kg) of grease. When reservoir is filled, grease will appear at upper pipe plug hole (12). 5. Remove supply hose from grease coupler. Remove excess grease from coupler. Install pipe plug (12) and tighten to standard torque.