Maintenance - Section 42 OM4204 Page 42-6 Automatic Lubrication System Injectors (SL-1 Series H) Injector Specifications a. Each lube injector services only one grease point. In case of pump malfunction, each injector is equipped with a covered grease fitting to allow the use of external lubricating equipment. b. Injectors are available in banks of two, three, four and five as well as single replacement units. c. Injector output is adjustable: Maximum output = 1.31 cc (0.08 in 3 ). Minimum output = 0.13 cc (0.008 in 3 ). d. Operating Pressure:
Minimum - 130 kg/cm 2 (1850 psi) Maximum - 246 kg/cm 2 (3500 psi) Recommended - 176 kg/cm 2 (2500 psi) Maximum Vent Pressure - (Recharge) 42 kg/cm 2 (600 psi) FIGURE 42-8. TYPE SL-1 INJECTOR (SINGLE) 1. Adjusting Screw 2. Locknut 3. Piston Stop Plug 4. Gasket 5. Washer 6. Viton O-Ring 7. Injector Body Assy. 8. Piston Assembly 9. Fitting Assembly 10. Plunger Spring 11. Spring Seat 12. Plunger 13. Viton Packing 14. Inlet Disc 15. Viton Packing 16. Washer 17. Gasket 18. Adapter Bolt 19. Adapter 20. Viton Packing The injectors may be adjusted to supply from 0.13 to 1.31 cc (0.008 in 3 to 0.08 in 3 ) of lubricant per injec- tion cycle.
The injector piston travel distance deter- mines the amount of lubricant supplied. This travel is in turn controlled by an adjusting screw in the top of the injector housing. Injector Adjustment Turn the adjusting screw (1, Figure 42-8) counter- clockwise to increase lubricant amount delivered and clockwise to decrease the lubricant amount. NOTE: The Piston Assembly (8) has a visible indicator pin at the top of the assembly to verify the injector operation. When the injector is not pressurized, maximum injec- tor delivery volume is attained by turning the adjust- ing screw (1) fully counterclockwise until the indicating pin (8) just touches the adjusting screw.
At the maximum delivery point, about 9.7 mm (0.38 in.) adjusting screw threads should be showing. Decrease the delivered lubricant amount by turning the adjusting screw clockwise to limit injector piston travel. If only half the lubricant is needed, turn the adjusting screw to the point where about 4.8 mm (0.19 in.) threads are showing. The injector will be set at minimum delivery point with about 0.22 mm (0.009 in.) thread showing. NOTE: The above information concerns adjustment of injector delivery volume. The timer adjustment should also be changed, if overall lubricant delivery is too little or too much. Injector output should NOT be adjusted to less than one-fourth capacity.
Figure 42-8A. INJECTOR (MANIFOLD TYPE)