SEN01352-00 10 Structure, function and maintenance standard 4. When there is abnormally high pressure. q When pressure (PR) of the self pressure reducing valve becomes abnormally high, ball (10) pushes against the force of spring (9), separates from the seat, and allows hydraulic oil to flow from output port (PR) o (T), so pres- sure (PR) goes down. This action protects the equipment at the destination for the hydraulic pressure supply (PPC valve, electromagnetic valve, etc.) from abnormally high pressure. (See Fig. 4) 14 BR380JG-1E0