10 Structure, function and maintenance standard SEN01354-00 Abnormal load stop system 1 Function q This system receives the signal from the pres- sure sensor installed to the inlet circuit of each actuator and inputs it to the CR710 controller for control. If the inlet pressure of each actua- tor increases above the set pressure, the whole work equipment, excluding the engine and travel unit, stops immediately. q If a steel block etc. is put in the crusher and the lock cylinder slips in the crusher clearance opening direction, the crusher stops immedi- ately. a For slip of the lock cylinder, see “Crusher tooth tip adjustment system”, Judgment of slip of lock cylinder.
q If this function operates, the horn sounds for 5 seconds. q After the work equipment is stopped by this function, the lamp to show the abnormal sec- tion lights up on the machine monitor. a For the lamp, see “Display of working mode”, Condition for turning work equipment lamp ON. BR380JG-1E0 3 Contents of error Set abnormal load pressure MPa {kg/cm2} Abnormal pressure on primary conveyor 19.6 {200} Abnormal pressure on side conveyor 12.3 {125} Abnormal pressure on magnetic separator 12.3 {125} Abnormal pressure on secondary conveyor 12.3 {125} Abnormal pressure on vibratory screen 19.6 {200}