10 Structure, function and maintenance standard SEN01355-00 q If an abnormal load is applied and a red lamp lights up (See the table on the next page), depress return switch (9) or restart the abnor- mally loaded work equipment, and the lamp is reset. Conditions for lighting work equipment lamp * 1. An overload on the crusher means that an excessive pressure load is applied to the crusher. * 2. An abnormal load on the crusher means that the crusher lock cylinder slips in the clearance increasing direction or the swing tooth moves into the maximum crusher clearance range. * 3.
A red lamp lighting because of an abnormal load is reset when "return" switch (9) is depressed or the abnormally loaded work equipment is restarted.
BR380JG-1E0 43 Conveyor Crusher Feeder Magnetic separator Side con- veyor (If equipped) Secondary conveyor (If equipped) Vibratory screen (If equipped) Stop White lamp W lights up l hite lamp ights up White lamp lights up Transparent Transparent Transparent Transparent Forward drive White lamp W lights up l hite lamp ights up White lamp lights up Transparent Transparent Transparent Transparent Reverse drive W — l hite lamp ights up — — — — — Overload R — fla ed lamp shes (*1) — — — — — Abnormal load R Red lamp l lights up ed lamp ights up (*2, 3) — Red lamp lights up Red lamp lights up Red lamp lights up Red lamp lights up Stopped under overload — — Green lamp flashes — — — —