Kaiyi BR380JG-1E0 — MACHINE MONITOR SYSTEM

SEN01355-00 10 Structure, function and maintenance standard Inspection mode q If work mode (B) is selected with the mode selector switch (2), you can check the operat- ing condition of each work equipment and find out the work equipment receiving an overload or abnormal load. q The inspection mode has the manual (M), semiautomatic (S), and automatic (A) modes, each which is selected by operating crusher clearance adjustment mode selector switch (2). 2. Semiautomatic (S) 1) Just after this screen appears, the cursor is at clearance set settle monitor (11). 2) Depress UP switch (5) or DOWN switch (6) of the monitor to bring the cursor to crusher clearance set value monitor (12).

3) Depress settle switch (7), and clearance set value (12) lights up. 4) Depress UP switch (5) or DOWN switch (6) of the monitor to bring the cursor to the clearance set settle monitor and depress the settle switch (7). 5) Clearance set value (12) flashes and the clearance is increased or decreased as explained below. 1. Manual (M) q While clearance closing switch (3) of the monitor is depressed, clearance closing monitor (8) flashes and actual crusher clearance value (10) changes. q When clearance set value (12) is +: The clearance is increased by the value of (12) from current actual crusher clearance (10).

q While clearance opening switch (4) of the monitor is depressed, clearance opening monitor (9) flashes and actual crusher clearance value (10) changes. a If actual crusher clearance value (10) is smaller than 50 mm or larger than 150 mm, it lights up red. q When clearance set value (12) is –: The clearance is decreased by the value of (12) from current actual crusher clearance (11). 6) While the crusher clearance is increasing, (9) flashes. While the former is decreas- ing, (8) flashes. a The input value to crusher clearance set value (12) is so limited that the actual crusher clearance will be in the effective using range of 50 – 150 mm.

When crusher clearance set value (12) is increased or decreased and settle switch (7) is depressed, if the actual crusher clearance is out of the above range, the crusher clearance set value is returned to the former value. 44 BR380JG-1E0