Kaiyi BR380JG-1E0 — MACHINE MONITOR SYSTEM

SEN01355-00 10 Structure, function and maintenance standard 5. On the input screen (where symbols of a lock and a key are displayed), input a 4-digit num- ber and depress input check switch (3). After the input check switch is depressed, the system urges you to input the same 4-digit number again for reconfirmation. Input the same 4-digit number and depress input check switch (3) to settle it. When inputting the number first time, "1" is dis- played at the right top of the screen. When inputting the number second time, "2" is dis- played. After the input number is settled, the ordinary screen appears.

a If the number input first time is different from that input second time, the password is not settled but the screen to input the number first time appears again. Function of checking service meter q When the starting switch is turned OFF, if return switch (1) and operation switch (2) of the monitor are depressed and held simulta- neously, the service meter is indicated on the display. q If the switches are released, the service meter disappears. It takes 3 - 5 seconds to display the service meter after depressing the switches. 52 BR380JG-1E0