SEN02288-00 20 Standard value table 4 BR380JG-1E0 Applicable Model BR380JG-1E0 Categ ory Check Item Measurement Condition Unit Standard value Permissible value Oil pressure Unload pressure • Oil temperature: 45 – 55°C • Run engine at full throttle • Set all levers in neutral • Pump outlet pressure MPa {kg/cm2} 3.9 ± 1.0 {40 ± 10} 3.9 ± 1.0 {40 ± 10} Crusher motor Forward Reverse • Oil temperature:
45 – 55°C • Run engine at full throttle • Pump outlet pressure • Relieve only circuit to be measured Forward 38.7 ± 1.5 {395 ± 15} 38.7 ± 2.0 {395 ± 20} Reverse 38.7 ± 1.5 {395 ± 15} 38.7 ± 2.0 {395 ± 20} Belt conveyor motor 23.0 ± 1.0 {235 ± 10} 23.0 ± 1.5 {235 ± 15} Feeder motor 21.0 ± 1.5 {215 ± 15} 21.0 ± 2.0 {215 ± 20} Release of lock cylinder 32.3 ± 1.0 {330 ± 10} 32.3 ± 1.5 {330 ± 15} Operation of lock cylinder (Extension, retraction) 11.8 ± 1.0 {120 ± 10} 11.8 ± 1.5 {120 ± 15} Conveyor elevator cylinder 23.5 ± 1.0 {240 ± 10} 23.5 ± 1.5 {240 ± 15} Side conveyor elevator cylinder 26.5 ± 1.0 {270 ± 10} 26.5 ± 1.5 {270 ± 15} Side conveyor motor 14.7 ± 1.0 {150 ± 10} 14.7 ± 1.5 {150 ± 15} Magnetic separator motor 19.6 ± 1.0 {200 ± 10} 19.6 ± 1.5 {200 ± 15} Left travel 39.2+1.0 –1.5 {400+10} –15 39.2+1.0 –2.5 {400+10} –25 Right travel 39.2+1.0 –1.5 {400+10} –15 39.2+1.0 –2.5 {400+10} –25 Self pressure reducing valve 3.04 – 3.43 {31 – 35} 2.84 – 3.43 {29 – 35} LS differential pressure • Oil temperature:
45 – 55°C • Rung engine at full throttle a LS differential pressure = Pump outlet pressure – LS pressure Turn all work equipment switches OFF 3.9 ± 1.0 {40 ± 10} 3.9 ± 1.0 {40 ± 10} Run all work equipment idle 0.98 ± 0.2 {10 ± 2} 0.98 ± 0.2 {10 ± 2}