Kaiyi BR380JG-1E0 — MEASURING FUEL RETURN RATE AND LEAKAGE

SEN02303-00 30 Testing and adjusting Measuring fuel return rate and leakage 1 a Measuring tools for fuel return rate and leakage 4) Run the engine at low idle and measure the return rate in 1 minute with measuring cylinder H4 . a If the return rate from the supply pump is in the following range, it is normal. a Since some fuel flows out during check, pre- pare receiving pan of about 20 liters. k Stop the machine on a level ground. 1. Measuring return rate from supply pump 1) Open the engine hood and disconnect return hose (1) of the supply pump. a The return hose is connected by a quick coupler.

k If the engine cannot be started, you may measure the fuel return rate while rotating the engine with the starting motor. Do not rotate for more than 20 seconds continu- ously, however, for protection of the starting motor. 2) Install connector H3 and cap nut [1] of tester kit H1 to the return hose to stop the fuel from flowing out. 3) Connect test hose [2] of tester kit H1 to the supply pump. a Lay the test hose so that it will not slacken and put its end in the receiv- ing pan. 5) After finishing measurement, remove the measuring tools and return the removed parts. a When measuring the leakage from the pressure limiter or finishing the measurement:

Return the removed parts to their original positions. a When measuring the leakage from the injector: Leave the removed parts as they are and keep the hose end in the receiving pan. 18 BR380JG-1E0 Symbol Part No. Part name H 1 795-790-4700 Tester kit 2 795-790-6700 Adapter 3 6754-71-5340 Connector 6754-71-5350 Washer 4 Commercially available Measuring cylinder 5 Commercially available Stopwatch At low idle 1,000 cc/min During cranking 140 cc/min