30 Testing and adjusting SEN02303-00 2. Measuring leakage from pressure limiter 1) Open the engine hood and disconnect return hose (2) of the pressure limiter. a Install the seal washer to the connec- tor bolt. 5) After finishing measurement, remove the mea- suring tools and return the removed parts. 3 Joint bolt: 24 ± 4 Nm {2.4 ± 0.4 kgm} 2) Install removed connector bolt (3) and cap nut [1] of tester kit H1 to the return hose to stop the fuel from flowing out. 3) Install connector H3 to the common rail and connect test hose [2] of tester kit H1 . a Lay the test hose so that it will not slacken and put its end in the receiv- ing pan. 3.
Measuring return rate from injector a The leakage from the injector is measured while the return hose of the pressure lim- iter is connected. Accordingly, before measuring the leakage from the injector, check that the leakage from the pressure limiter is normal. 1) Referring to “Measuring return rate from supply pump”, set the supply pump for testing. k The fuel returning from the supply pump flows out during measure- ment of the return rate from the injector. Accordingly, keep the test hose end in the receiving pan. 2) Disconnect return hose (4) of the return block. a Install the seal washer to the return hose.
4) Run the engine at low idle and measure the return rate in 1 minute with measuring cylinder H4 . a If the leakage from the pressure limiter is in the following range, it is normal. BR380JG-1E0 19 At low idle 0 cc (No leakage)