Kaiyi BR380JG-1E0 — BLEEDING AIR FROM FUEL CIRCUIT

SEN02303-00 30 Testing and adjusting 3) Install connector bolt [3] of adapter H2 instead of the removed connector bolt, and connect test hose [4]. a Lay the test hose so that it will not slacken and put its end in the receiv- ing pan. Bleeding air from fuel circuit 1 a If fuel is used up or if a fuel circuit part is removed and installed, bleed air from the fuel circuit according to the following procedure. k Stop the machine on a level ground. 1. Fill the fuel tank with fuel. a Add fuel until the float of the sight gauge reaches the maximum position. 2. Open the under cover of the pump room. 3. Loosen knob (1) of the feed pump and pull it out, and then operate it forward and backward.

a Move the knob until it becomes heavy. a The plug at the top of the fuel main filter does not need to be removed. 4) Run the engine at low idle and measure the return rate in 1 minute with measuring cylinder H4 . a If the return rate from the injector is in the following range, it is normal. k If the engine cannot be started, you may measure the fuel return rate while rotating the engine with the starting motor. Do not rotate for more than 20 seconds continu- ously, however, for protection of the starting motor. 4. After bleeding air, push in and tighten knob (1). 5) After finishing measurement, remove the measuring tools and return the removed parts. 3 Joint bolt:

24 ± 4 Nm {2.4 ± 0.4 kgm} 20 BR380JG-1E0 At low idle 180 cc/min During cranking 90 cc/min