Kaiyi BR380JG-1E0 — SPECIAL FUNCTIONS OF MACHINE MONITOR

SEN02304-00 30 Testing and adjusting 21. Function of abnormality record [02] 3) Contents of display of electrical system abnormality record information screen (1): Occurrence order of abnormalities from latest one/Total number of records (2): Failure code (Equipment: 4 digits, Phenomena: 2 digits) (3): Elapsed time on service meter from the first occurrence (4): Contents of trouble a See the operator menu “Failure codes table”. The machine monitor records and classifies the past failure information as into the electri- cal and mechanical failures. It allows display- ing and checking the information through the following operations.

1) Menu selection Select “02 Abnormality Record” in the ini- tial display of Service Menu and depress [ ] switch. 2) Sub menu selection Select the sub menu from the abnormality record menu screen and then press [ ] switch. 4) Contents of display of mechanical system abnormality record information screen (1): Record number (2): Contents of trouble (3): Failure code (Equipment: 4 digits, Pheomena: 2 digits) (4): Total number of occurrences (5): Service meter reading at first occur- rence a See the operator menu “Failure codes table”. 20 BR380JG-1E0 Number Sub menu of abnormality record 00 Return (End of abnormality record) 01 Electrical systems 02 Mechanical systems