30 Testing and adjusting SEN02305-01 4. Set mode selector switch (2) to INSPECTION (c) position. The machine monitor switches to the normal inspection screen. 6. Check that mode monitor (D) of the machine monitor has changed to S (semi-automatic) mode, then input clearance value (A) for the amount to change the present clearance on the machine monitor as follows. 1) Use UP switch (4) or DOWN switch (5) to move the cursor on the screen display to position (A). 5. Set clearance adjustment selector switch (3) to the S (semi-automatic) position. 2) Press input confirmation switch (6). (A) starts flashing and numeral input window (B) is displayed at the top left of the screen.
3) Use UP switch (4) or DOWN switch (5) to increase or decrease the value on the dis- play and adjust to give the desired set value. The numerical value can be set in units of 1 mm in a range of 50 to 150 mm. + display: Adjustment to open clearance – display: Adjustment to close clearance If the UP switch (4) or DOWN switch (5) is kept pressed continuously, the set value will increase or decrease in units of 10 mm . 4) After inputting the set value for the adjust- ment, press input confirmation switch (6) to set the input value. BR380JG-1E0 9