Kaiyi BR380JG-1E0 — PREPARATION WORK FOR TROUBLESHOOTING FOR ELECTRICAL SYSTEM

SEN02305-01 30 Testing and adjusting 7. Supply pump IMV solenoid (FUEL REGU- LATOR) a Disconnection and connection of con- nector The connector of the supply pump IMV solenoid has a special locking mecha- nism. Disconnect it according to steps (a) – (b) and connect it according to steps (c) – (d) as shown below. Disconnection : (a) Unlock – (b) Discon- nect connector. Connection : (c) Connect connector – (d) Lock. a Precautions for disconnecting connector The direction of the lock of the connector varies with the tightened position of the sensor and the lock may be in a direction in which it is difficult to reset (on the under- side or engine side).

In this case, pinch the lock in direction (a) with bent-nose nippers [1] (commercially available), and the lock is reset. Since the lock clicks when it is reset, dis- connect the connector after a click is heard. a Precautions for connecting connector Take care not to connect the connector reversely. Engage lock (e) on the wiring harness side with triangular notch (f) on the sensor side (Do not engage lock (e) with square guide (g) on the opposite side of triangular notch (f)). 8. Common rail pressure sensor (FUEL RAIL PRESS) a Disconnection and connection of con- nector The connector of the common rail pres- sure sensor has a special locking mecha- nism.

Disconnect it according to steps (a) – (b) and connect it according to steps (c) – (d) as shown below. Disconnection : (a) Unlock – (b) Discon- nect connector. Connection : (c) Connect connector – (d) Lock. 58 BR380JG-1E0