SEN02091-00 40 Troubleshooting Failure code [7RFHKB] Short circuit in conveyor forward relay 1 14 BR380JG-1E0 User code Failure code Trouble Short circuit in conveyor forward relay (Work equipment and pump controller (work equipment control) system) — 7RFHKB Contents of trouble • When the conveyor forward rotation relay circuit is driven, ground short circuit is detected. Action of controller • Turns the output to the conveyor forward rotation relay OFF. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that appears on machine • The conveyor forward rotation does not work.
• Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The drive state (ON/OFF) of the conveyor forward relay solenoid can be checked with the monitor- ing function (Code: 25602, Relay Drive 1) • Since the controller detects ground short circuit while the conveyor forward solenoid is driven, be sure to turn the solenoid output ON when checking reproduction of the failure after repair. • This failure code is generated when the primary (coil side) of conveyor forward relay has failed. A failure of the secondary (contact side) cannot be detected with this code. • The failure history is recorded.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective conveyor for- ward rotation relay (Internal disconnec- tion) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. R16 (male) Resistance Between (1) and (2) 100 – 500 z 2 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (5) – R16 (female) (1) and chassis ground Resistance Min.
1 Mz 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C03 (female) Resistance Between (5) and chassis ground 100 – 500 z