Kaiyi BR380JG-1E0 — FAILURE CODE [7RFCKY] SHORT CIRCUIT IN MAGNETIC SEPARATOR SOLENOID

SEN02091-00 40 Troubleshooting Failure code [7RFCKY] Short circuit in magnetic separator solenoid 1 Related electrical circuit diagram 12 BR380JG-1E0 User code Failure code Trouble Short circuit in magnetic separator solenoid (Work equipment and pump controller (work equipment control) system) — 7RFCKY Contents of • trouble When magnetic separator solenoid is not driven, hot short of the circuit (contact with 24 V circuit) is detected. Action of • controller None in particular. Problem that • appears on machine • The magnetic separator does not stop.

(If it does not stop, press the engine stop switch or turn OFF the engine starting switch.) Horn sounds (three intermittent sounding) upon detecting a failure. • Related information • The driven state (ON/OFF) of the magnetic separator solenoid can be checked with the monitoring function (Code: 25500, Solenoid Valve) The failure history is recorded. 1 Possible causes and standard value 2 in normal state 3 Cause Standard value in normal state/Remarks on troubleshooting Defective magnetic separator solenoid (Internal defect) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.

AV4 (male) Resistance Between (1) and (2) 20 – 60 z Hot short in wiring har- ness (Contact with 24V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting Wiring harness between C03 (female) (25) – A02 – AV4 (female) (2) and chassis ground Voltage Max. 1 V Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting without. C03 (female) Voltage Between (25) and chassis ground Max. 1 V