Kaiyi BR380JG-1E0 — FAILURE CODE [7RFCKB] SHORT CIRCUIT IN MAGNETIC SEPARATOR SOLENOID

40 Troubleshooting SEN02091-00 Failure code [7RFCKB] Short circuit in magnetic separator solenoid 1 Related electrical circuit diagram BR380JG-1E0 11 User code Failure code Trouble Short circuit in magnetic separator solenoid (Work equipment and pump (work equipment control) controller system) — 7RFCKB Contents of • trouble When the magnetic separator solenoid is driven, ground short circuit is detected. • Action of • controller Turns the output to the magnetic separator solenoid OFF. Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that • appears on • machine The magnetic separator does not work.

Horn sounds (three intermittent sounding) upon detecting a failure. • Related • information • The driven state (ON/OFF) of the magnetic separator solenoid can be checked with the monitoring function (Code: 25500, Solenoid Valve) Since the controller detects the ground short circuit while the magnetic separator solenoid is driven, be sure to turn the solenoid output ON when checking reproduction of the failure after repair. The failure history is recorded.

1 Possible causes and standard value 2 in normal state 3 Cause Standard value in normal state/Remarks on troubleshooting Defective magnetic separator solenoid (Internal short circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. AV4 (male) Resistance Between (1) and (2) 20 – 60 z Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (25) – A02 – AV4 (female) (2) and chassis ground Resistance Min.

1 Mz Defective work equip- ment and pump controller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C03 (female) Resistance Between (25) and chassis ground 20 – 60 z