Kaiyi BR380JG-1E0 — FAILURE CODE [7RFMKY] SHORT CIRCUIT IN ABNORMAL PRESSURE RELAY

SEN02091-00 40 Troubleshooting Failure code [7RFMKY] Short circuit in abnormal pressure relay 1 26 BR380JG-1E0 User code Failure code Trouble Short circuit in abnormal pressure relay (Work equipment and pump controller (work equipment control) system) — 7RFMKY Contents of trouble • When the abnormal pressure recovery relay circuit is driven, hot short (contact with 24 V circuit) is detected. Action of controller • Turns the output to the abnormal pressure recovery relay circuit OFF. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF.

Problem that appears on machine • The secondary conveyor, water spray, and vibratory screen do not work. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The drive state (ON/OFF) of the abnormal pressure relay can be checked with the monitoring func- tion (Code: 25601, Relay Drive 0) • Since the controller detects a hot short (contact with 24 V circuit), turn the output ON for reproduc- tion check after recovery. • This failure code is generated when the primary (coil side) of abnormal pressure recovery relay has failed. A failure of the secondary (contact side) cannot be detected with this code. • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective abnormal pressure recovery relay (Internal short cir- cuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. R05 (male) Resistance Between (1) and (2) 100 – 500 z 2 Hot short in wiring har- ness (Contact with 24V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Wiring harness between C02 (female) (18) – R05 (female) (2) and chassis ground Voltage Max.

1 V 3 Defective work equip- ment and pump controller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C02 (male) Resistance Between (18) and chassis ground 100 – 500 z