Kaiyi BR380JG-1E0 — FAILURE CODE [7RJAKY] SHORT CIRCUIT IN TRAVEL LOCK EPC SOLENOID VALVE

SEN02091-00 40 Troubleshooting Failure code [7RJAKY] Short circuit in travel lock EPC solenoid valve 1 Related electrical circuit diagram 44 BR380JG-1E0 User code Failure code Troubl 7RJAKY Short circuit in travel lock EPC solenoid valve e (Work equipment and pump controller (work equipment control) system) — Contents of trouble • When the travel lock EPC valve solenoid is not driven, hot short circuit (contact with 24 V circuit) is detected). Action of controller • None in particular. • When the cause of failure disappears, system is reset by itself. Problem that appears on machine • The travel speed increases (equivalent to the “Mi” gear position) in the “Lo” position.

• Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Hot short in wiring ha ness (Contact with 24 circuit) aPrepare with engine starting switch OFF, then turn engine starting r- switch ON and carry out troubleshooting. V Wiring harness between C03 (female) (35) – V11 Voltage Max. 1 V (female) (2) and chassis ground Voltage Max . 1 V 2 Defective work equip ment and pump controller - If cause 1 is not detected, work equipment and pump controller may be defective.

(Since trouble is in system, troubleshooting cannot be carried out.)