Kaiyi BR380JG-1E0 — FAILURE CODE [7RJNMA] ABNORMALITY IN VIBRATORY SCREEN PRESSURE SENSOR

SEN02091-00 40 Troubleshooting Failure code [7RJNMA] Abnormality in vibratory screen pressure sensor 1 46 BR380JG-1E0 User code Failure code Trouble Abnormality in vibratory screen pressure sensor (Work equipment and pump controller (work equipment control) system) — 7RJNMA Contents of trouble • Signal voltage from the vibratory screen pressure sensor is below 0.3 V or above 4.42 V. Action of controller • Mistakes the vibratory screen pressure for 0 MPa. • If cause of failure disappears, system resets itself.

Problem that appears on machine • Whole work equipment does not stop completely even if abnormal load is applied to the vibratory screen (primary conveyor, crusher, feeder, muck discharge conveyor, magnetic separator, vibratory screen and secondary conveyor). • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • Input from the vibratory screen pressure sensor can be checked with the monitoring function (Code: 25801, Vibrator Screen Pressure). • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5 V sensor power supply system If failure code [DA25KP] is displayed simultaneously, carry out the trouble- shooting for it first 2 Defective vibratory screen pressure sen- sor (Internal failure) aPrepare with engine starting switch OFF, then turn engine starting switch ON or START and carry out troubleshooting. S07 (male) Voltage Between (1) and (3) 4.5 – 5.5 V Between (1) and (2) 0.3 – 4.5 V If the voltage is normal, replace with another pressure sensor (pressure sensor of conveyor etc.) and check if failure codes are displayed.

(If the E mark of the failure code disappears, the vibratory screen pressure sensor is defective.) 3 Disconnection in wir- ing harness (Discon- nection or defective contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (3) – A21 – S07 (female) (2) Resistance Max. 1 z Wiring harness between C01 (female) (4), (10) – A21 – S07 (female) (1) Resistance Max. 1 z Wiring harness between C01 (female) (22) – A21 – S07 (female) (3) Resistance Max.

1 z 4 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (3) – A21 – S07 (female) (2) and chassis ground Resistance Min. 1 Mz 5 Hot short in wiring har- ness (Contact with 24V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Wiring harness between C01 (female) (3) – A21 – S07 (female) (2) and chassis ground Voltage Max. 1 V Wiring harness between C01 (female) (22) – A21 – S07 (female) (3) and chassis ground Voltage Max.

5 V 6 Defective work equip- ment and pump con- troller If causes 1 – 5 are not detected, work equipment and pump controller may be defective. (Since trouble is in system, troubleshooting cannot be car- ried out.)