Kaiyi BR380JG-1E0 — FAILURE CODE [7RJQKB] SHORT CIRCUIT IN RADIO CONTROL TRAVEL-MODE SWITCH

40 Troubleshooting SEN02091-00 Failure code [7RJQKB] Short circuit in radio control travel-mode switch 1 Related electrical circuit diagram BR380JG-1E0 49 User code Failure code Trouble Short circuit in radio control travel-mode switch (Work equipment and pump controller (work equipment control) system) — 7RJQKB Contents of trouble • Input signal circuit for the radio controller travel selector switch is closed (connected to ground cir- cuit) within 1 second after the engine starting switch ON. Action of controller • Turns the travel lock EPC output OFF in Radio Control mode.

(Panel mode can output ON signal.) • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that appears on machine • The travel operation is disabled. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The input state (ON/OFF) of the radio control travel-mode switch can be checked with the monitor- ing function (Code: 25001, Switch Input 1) • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective radio control- 1 ler receiver aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between A33 (male) (15) and chassis grou nd Resistanc e Min. 1 Mz Grounding fault in wir- 2 ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (19) (female) (15) and chassis ground – A33 Resistanc e Min.

1 Mz Defective work equip- 3 ment and pump controller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between C03 (female) (19) and chassis gr ound Resistanc e Min. 1 Mz