Kaiyi BR380JG-1E0 — FAILURE CODE [7RJRKB] SHORT CIRCUIT ON TRAVEL SIGNAL

SEN02091-00 40 Troubleshooting Failure code [7RJRKB] Short circuit on travel signal 1 50 BR380JG-1E0 User code Failure code Trouble Short circuit on travel signal (Work equipment and pump controller (work equipment control) system) — 7RJRKB Contents of trouble • Travel signal circuit is closed (connected to ground circuit) within 1 second after the engine starting switch ON. Action of controller • Turns the output to the travel lock EPC OFF. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that appears on machine • The machine does not travel. • Horn sounds (three intermittent sounding) upon detecting a failure.

Related information • The input state (ON/OFF) of the radio control travel signal switch can be checked with the monitor- ing function (Code: 25001, Switch Input 1) • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel lock EPC pressure switch aPrepare with engine starting switch OFF and radio control work-mode switch on panel side, then carry out troubleshooting after starting the engine. S23 (male) Mode selector switch Resistance Between (1) and (2) Working mode Min. 1 Mz Travel mode aSet the conveyor to the travel operation position (upper posi- tion). Max.

1 z 2 Defective travel signal pressure switch aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. C05 (male) Travel operation Resistance Between (1) and (2) Traveling Max. 1 z Holds in position. Min. 1 Mz 3 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (29) – R03 (female) (2) and chassis ground Resistance Min. 1 Mz Wiring harness between C03 (female) (29) – S23 (female) (1) and chassis ground Resistance Min.

1 Mz Wiring harness between S23 (female) (2) – A08A – D10 (5), (6), (7), (8) and chassis ground Resistance Min. 1 Mz Wiring harness between S23 (female) (2) – A08A – A08B – S05 (female) (2) and chassis ground Resistance Min. 1 Mz 4 Defective work equip- ment and pump con- troller If causes 1 – 3 are not detected, work equipment and pump controller may be defective. (Since trouble is in system, troubleshooting cannot be car- ried out.)