SEN02093-00 40 Troubleshooting Failure code [CA488] Charge temperature too high and torque derated 1 Failure code [CA553] Common rail pressure sensor too high (1) 1 26 BR380JG-1E0 User code Failure code Trouble Charge temperature too high and torque derated (Engine controller system) E11 CA488 Contents of trouble • Temperature signal of boost pressure/temperature sensor exceeded control upper temperature limit. Action of controller • Limits output and continues operation. Problem that appears on machine • Engine output lowers. Related information • Boost temperature can be checked with monitoring function. (Code: 18500, Charge Temperature) • Method of reproducing failure code: Start engine.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Lowering of cooling performance of after- cooler Cooling performance of aftercooler may be low. Check following points directly. • Looseness and breakage of fan belt. • Insufficiency of cooling air • Clogging of aftercooler fins 2 Abnormal rise of turbo- charger outlet temper- ature Outlet temperature of turbocharger may be abnormally high. Check related parts directly. 3 Defective engine controller If causes 1 – 2 are not detected, engine controller may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.) User code Failure code Trouble Common rail pressure sensor too high (1) (Engine controller system) E15 CA553 Contents of trouble • There is high pressure error in common rail circuit. Action of machine moni- tor • None in particular. Problem that appears on machine • Engine sound becomes large when no or light load is applied. • Engine output lowers. Related information • Common rail pressure can be checked with monitoring function. (Code: 36400, Rail Pressure) • Method of reproducing failure code: Start engine.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defect in related sys- tem If another failure code is displayed, carry out troubleshooting for it. 2 Defective connection of ground terminal Ground terminal may be connected defectively. Check following terminals directly. • Ground terminal of machine ((–) terminal of battery) • Ground terminal of engine • Ground terminal of engine controller • Ground terminal of starting motor 3 Breakage of O-ring of supply pump actuator O-ring of supply pump actuator may be broken. Check it directly.