Kaiyi BR380JG-1E0 — FAILURE CODE [CA559] SUPPLY PUMP NO PRESSURE

40 Troubleshooting SEN02093-00 Failure code [CA559] Supply pump no pressure 1 BR380JG-1E0 27 User code Failure code Trouble Supply pump no pressure (Engine controller system) E15 CA559 Contents of trouble • There is low pressure error in common rail circuit. Action of controller • None in particular. Problem that appears on machine • Engine does not start at all or does not start easily. • Exhaust gas becomes black. • Engine output lowers. Related information • Common rail pressure can be checked with monitoring function. (Code: 36400, Rail Pressure) • Method of reproducing failure code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Fuel leakage to outside Fuel may be leaking to outside. Check it directly (Check visually while run- ning engine at low idle). 2 Defect in low pressure circuit parts aFor check of pressure in fuel low pressure circuit, see Testing and adjusting, Checking fuel pressure.

Pressure in fuel low-pressure circuit During cranking (if engine cannot be started) 0.3 – 1.1 MPa {3.1 – 11.3 kg/cm2} During low idle (if engine can be started) 0.5 – 1.3 MPa {5.1 – 13.3 kg/cm2} 3 Defective pressure limiter aFor check of leakage through pressure limiter, see Testing and adjust- ing, Checking fuel return rate and leakage. Leakage through pres- sure limiter During low idle 0 cc (No leakage) 4 Defective injector (including high pres- sure piping in head) aFor check of return rate from injector, see Testing and adjusting, Check- ing fuel return rate and leakage. Return rate from injector During cranking (if engine cannot be started) Max. 90 cc/min.

During low idle (if engine can be started) Max. 180 cc/min. 5 Defective supply pump aFor check of return rate from supply pump, see Testing and adjusting, Checking fuel return rate and leakage. Return rate from supply pump During cranking (if engine cannot be started) Max. 140 cc/min. During low idle (if engine can be started) Max. 1,000 cc/min.