40 Troubleshooting SEN02094-00 BR380JG-1E0 11 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 3 Hot short in wiring harness (Contact with 24 V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting Wiring harness between C01 (female) (22) – J03 – S01 (female) (3) and chassis ground [Primary conveyor pressure sensor system] Voltage Max. 5.3V Wiring harness between C01 (female) (22) – J03 – S02 (female) (3) and chassis ground [Muck discharge conveyor pressure sensor sys- tem] Voltage Max.
5.3V Wiring harness between C01 (female) (22) – J03 – S03 (female) (3) and chassis ground [Magnetic separator pressure sensor system] Voltage Max. 5.3V Wiring harness between C01 (female) (22) – J03 – S10 (female) (3) and chassis ground [F pump pressure sensor system] Voltage Max. 5.3V Wiring harness between C01 (female) (22) – J03 – S11 (female) (3) and chassis ground [R pump pressure sensor system] Voltage Max. 5.3V Wiring harness between C01 (female) (22) – J03 – S12 (female) (C) and chassis ground [Clearance detection potentiometer system] Voltage Max.
5.3V Wiring harness between C01 (female) (22) – J06 – S06 (female) (3) and chassis ground [Secondary conveyor pressure sensor system] Voltage Max. 5.3V Wiring harness between C01 (female) (22) – J06 – S07 (female) (3) and chassis ground [Vibratory screen pressure sensor system] Voltage Max. 5.3V 4 Defective work equip- ment and pump con- troller If causes 1 – 3 are not detected, work equipment and pump controller may be defective. (Troubleshooting cannot be carried out since trouble is in system.)