Kaiyi BR380JG-1E0 — FAILURE CODE [DXA0KA] DISCONNECTION IN PC-EPC SOLENOID

SEN02094-00 40 Troubleshooting Failure code [DXA0KA] Disconnection in PC-EPC Solenoid 1 Related electrical circuit diagram 32 BR380JG-1E0 User code Failure code Trouble Disconnection in PC-EPC Solenoid (Work equipment and pump controller (pump control) system) E02 DXA0KA Contents o trouble f • When the PC-EPC solenoid is driven, disconnection of the circuit is detected. Action of controller • None in particular. (Since no current flows, solenoid does not operate.) • If cause of failure disappears, system resets itself. Problem th appears o machine at • When the pump load increases, engine speed lowers sharply and may cause engine stall.

n • Horn sounds (three intermittent sounding) upon detecting a failure. Related informatio • PC-EPC electric current value can be checked with the monitoring function. (Code: 01300, PC-EPC Sol. Curr.) n • The failure history is recorded. • Method of reproducing failure code: turn engine starting switch ON.

Possible causes an standard val in normal st Cause Defective PC-EPC 1 solenoid (Internal dis- connection) Disconnection in wiring d harness (Disconnec- ue 2 tion or defective con- ate tact in connector) Defective work equip- 3 ment and pump con- troller Standard value in normal state/Remarks on troubleshooting aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. V06 (male) Resistance Between (1) and (2) 7 – 14 z aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (16) – V06 (female) (1) Resistance Max.

1 z Wiring harness between C03 (female) (3) – V06 (female) (2) Resistance Max. 1 z aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C03 (female) Resistance Between (16) and (3) 7 – 14 z