Kaiyi BR380JG-1E0 — E-4 PREHEATER DOES NOT OPERATE

SEN02095-00 40 Troubleshooting E-4 Preheater does not operate 1 12 BR380JG-1E0 Trouble (1) When starting switch is turned to HEAT position, preheating monitor does not light up or flash. Related information • Preheater monitor lights up when starting switch is turned to HEAT and starts flashing about 30 sec- onds after to notify completion of preheating (It stops flashing about 10 seconds after). • If engine coolant temperature is below 20°C, automatic warm-up system operates and preheating monitor lights up for up to 30 seconds. • Condition of starting switch (preheating) signal can be checked with the monitoring function. (Code 04500:

Monitor input 1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective starting switch (Internal discon- nection) aPrepare with starting switch OFF, then keep starting switch OFF and turn it to HEAT and carry out troubleshooting in each case. Starting switch Starting switch Resistance Between B – R1 OFF Min. 1 Mz HEAT Max. 1 z 2 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between P02 (female) (18) – starting switch R1 Resistance Max.

1 z 3 Defective machine monitor aPrepare with starting switch OFF, then keep starting switch OFF and turn it to HEAT and carry out troubleshooting in each case. P02 Starting switch Voltage Between (18) – chassis ground OFF Max. 1 V HEAT 20 – 30 V Trouble (2) When starting switch is turned to HEAT position, intake air heater mounting part does not become warm. Related information • Check that engine can be turned with starting motor (If engine cannot be turned, carry out trouble- shooting for E-1 Engine does not start (Engine does not turn)).

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective heater relay (Internal disconnec- tion) aPrepare with starting switch OFF (with wiring harness connected), then keep starting switch OFF and turn it to HEAT and carry out trouble- shooting in each case. Heater relay Starting switch Continuity/Resistance Between T07 – chassis ground OFF There is continuity Between T06 – T05 HEAT Max. 1 z 2 Defective intake air heater (Internal discon- nection) aPrepare with starting switch OFF (with wiring harness connected), then turn starting switch to HEAT and carry out troubleshooting in each case.

E01 Starting switch Voltage Between terminal – chassis ground HEAT 20 – 30 V If voltage is normal but heater mounting part does not become warm, intake air heater is defective. 3 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between starting switch R1 – heater relay T07 Resistance Max. 1 z Wiring harness between battery relay M – heater relay T06 Resistance Max. 1 z Wiring harness between heater relay T05 – elec- trical intake air heater E01 Resistance Max. 1 z