SEN02095-00 40 Troubleshooting E-5 The whole work equipment stops suddenly 1 14 BR380JG-1E0 Trouble • The whole work equipment stops suddenly. Related information • The work equipment stops suddenly while no switches are operated in the following cases; (1) The work equipment is overloaded. (2) Engine has abnormality. In these cases, the horn sounds. • The work equipment may also stop when the mode selection switch or conveyor height sensor fail- ure is mistakenly detected. • Input of the mode selector switch/conveyor position sensor can be checked in the monitoring func- tion of the machine monitor.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective adjustment of conveyor position sensor aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Clearance between conveyor position sensor and detection plate Sensor Clearance When conveyor is up When conveyor is middle Conveyor up p sensor (A) osition a b 4 – 7 mm — 1 – 2 mm — Conveyor midd position sensor le a (B) b 4 – 7 mm 4 – 7 mm 1 – 2 mm 1 – 2 mm 2 Defective fuse No. 10 If fuse is broken, circuit probably has ground fault.
(See cause 6.) 3 Defective conveyor position sensor When the state of the conveyor up position sensor and conveyor middle position sensor on the monitor is different from the actual state, and when grounding fault is not found in the below conveyor position sensors, the conveyor position sensor may be defective Sensor When conveyo is up r When conveyor is middle When conveyor is low Conveyor up p sensor (A) osition ON (GND) OFF (24 V) OFF (24 V) Conveyor midd position sensor le ON (GND) (B) ON (GND) OFF (24 V) 4 Defective mode selector switch aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
B13 (male) Mode selector switch Resistance Between (2) – (4) Travel Max. 1 z Work Min. 1 Mz Inspection Min. 1 Mz Between (3) – (4) Travel Max. 1 z Work Max. 1 z Inspection Min. 1 Mz