Kaiyi BR380JG-1E0 — E-17 MACHINE DOES NOT TRAVEL

SEN02095-00 40 Troubleshooting E-17 Machine does not travel 1 34 BR380JG-1E0 Trouble • Machine does not travel Related information • Travel operation may be interlocked by (1) Mode selector switch or (2) conveyor height, rendering the machine unable to travel. For the machine equipped with the radio controller, radio controller switch can select the method for machine to travel by travel lever or by radio controller. Radio Travel Conveyor height Operating Mode controller speed method Up Middle Down switch selection Hi Q × Panel Mi Q Q × Lever Lo Q Q × Radio — × × × Travel controller Panel — × × × Radio Hi Q × Radio controller Mi Q Q × controller Lo Q Q × Lever — — × × × Panel — × × × Q :

Machine travels at Work Radio Hi × × selected speed. Radio : Machine travels at controller Mi × Q × controller Mi-speed although Hi Lo × Q × is selected. Testing — — — × × × × : Machine does not travel • The mode selector switch and conveyor height can be checked with the monitoring function. (Code 25002: Mode selector working switch, mode selector travel switch) (Code 25004: conveyor up position sensor, conveyor middle position sensor) • If traveling with the radio controller only does not work, refer to Troubleshooting E-18.

Mode Operating method Radio controller switch Travel speed selection Conveyor height Up Middle Down Travel Lever Panel Hi Q × Mi Q Q × Lo Q Q × Radio controller — × × × Radio controller Panel — × × × Radio controller Hi Q × Mi Q Q × Lo Q Q × Work Lever — — × × × Radio controller Panel — × × × Radio controller Hi × × Mi × Q × Lo × Q × Testing — — — × × × Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective mode selector switch or conveyor posi- tion sensor Defective wiring harness of switch system or sen- sor system Carry out troubleshooting related to the mode selector switch and conveyor position sensor, according to the troubleshooting E-5 (Working equipment stops completely in sudden).

2 Defective emergency travel actuation switch (Internal disconnection or short circuit) a Prepare with engine stopped, then run engine at high idle speed and carry out troubleshooting. Emergency travel actua- tion switch B38 (male) Emergency travel actua- tion switch Resistance (1) – (3) Ordinary side Max. 1 z Unordinary side Min. 1 Mz (6) – (8) Ordinary side Max. 1 z Unordinary side Min. 1 Mz 3 Disconnection in wiring harness (Disconnection or defec- tive contact) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. a Turn the emergency travel actuation switch to ordinary side and carry out trou- bleshooting.

Wiring harness between C03 (female) (35) – B38 – A01 (9) – V11 (female) (2) Resistance Max. 1 z Wiring harness between C03 (female) (13) (23) – B38 – A01 (10) – V11 (female) (1) Resistance Max. 1 z 4 When controller detects a trouble in the related sys- tem Check if the following failures are displayed in the electrical system failure history on the monitor. If displayed, see appropriate troubleshooting. Disconnection in travel lock EPC solenoid valve [7RJAKA] Short circuit in travel lock EPC solenoid valve [7RJAKB], [7RJAKY] 5 Defective controller a Prepare with engine stopped, then run engine at high idle speed and carry out troubleshooting.

C03 (female) Solenoid valve outlet pressure Between (35) – (13), (23) 7 – 4 z Between (35) – chassis ground Min. 1 Mz