Kaiyi BR380JG-1E0 — E-22 THE CRUSHER CANNOT BE OPERATED WITH THE CRUSHER MANUAL FORWARD/REVERSE SWITCH ON THE MONITOR

SEN02095-00 40 Troubleshooting E-22 The crusher cannot be operated with the crusher manual FORWARD/REVERSE switch on the monitor 1 48 BR380JG-1E0 Trouble • The crusher cannot be rotated forward or in reverse with the crusher manual FORWARD/ REVERSE switch on the monitor. Relative information • The crusher can be operated with the crusher manual FORWARD/REVERSE switch under the fol- lowing condition: (1) The mode selector switch is in the WORK or INSPECTION position and the crusher is stopped. (2) The radio control selector switch is in the PANEL position.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Communication abnormality If failure code [DA2RMC] (CAN communication error (pump controller)) is displayed, carry out troubleshooting for it first. 2 Disconnection in crusher forward EPC valve If failure code [7RF2KA] (Disconnection in crusher forward EPC solenoid) is displayed, carry out troubleshooting for it first. 3 Short circuit in crusher forward EPC valve If failure code [7RF2KB], [7RF2KY] (Short circuit in crusher forward EPC solenoid) is displayed, carry out troubleshooting for it first.

4 Disconnection in crusher reverse EPC valve If failure code [7RF3KA] (Disconnection in crusher reverse EPC solenoid) is displayed, carry out troubleshooting for it first. 5 Short circuit in crusher reverse EPC valve If failure code [7RF3KB], [7RF3KY] (Short circuit in crusher reverse EPC solenoid) is displayed, carry out troubleshooting for it first. 6 Defective monitor If the results of above checks 1 – 5 are normal, the monitor is probably defective.