Kaiyi BR380JG-1E0 — E-23 THE CONVEYOR CANNOT BE OPERATED WITH THE CONVEYOR MANUAL FORWARD/REVERSE SWITCH ON THE MONITOR

40 Troubleshooting SEN02095-00 E-23 The conveyor cannot be operated with the conveyor manual FORWARD/REVERSE switch on the monitor 1 BR380JG-1E0 49 Trouble • The conveyor cannot be rotated forward or in reverse with the conveyor manual FORWARD/ REVERSE switch on the monitor. Relative information • The conveyor can be operated with the conveyor manual FORWARD/REVERSE switch under the following condition: (1) The mode selector switch is in the INSPECTION position and the conveyor is stopped. (2) The radio control selector switch is in the PANEL position.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Communication abnormality If failure code [DA2RMC] (CAN communication error (pump controller)) is displayed, carry out troubleshooting for it first. 2 Short circuit in con- veyor forward relay If failure code [7RFHKB], [7RFHKY] (Short circuit in conveyor forward relay) is displayed, carry out troubleshooting for it first. 3 Disconnection or short circuit in conveyor reverse relay If failure code [7RD2KZ] (Disconnection or short circuit in conveyor reverse relay) is displayed, carry out troubleshooting for it first.

4 Short circuit in con- veyor reverse relay If failure code [7RD2KB] (Short circuit in conveyor reverse relay) is dis- played, carry out troubleshooting for it first. 5 Defective monitor If the results of above checks 1 – 5 are normal, the monitor is probably defective.