Kaiyi BR380JG-1E0 — E-24 KOMTRAX SYSTEM DOES NOT OPERATE NORMALLY

SEN02095-00 40 Troubleshooting E-24 KOMTRAX system does not operate normally 1 50 BR380JG-1E0 Trouble • KOMTRAX system does not operate normally. Related information • If KOMTRAX system administrator makes request for checking system on machine side for trouble, carry out following troubleshooting. • Even if KOMTRAX system has trouble, it does not particularly appear on machine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective power supply aTurn starting switch OFF, then carry out troubleshooting.

LED (1) Normal state LED-A1 Lighted up aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. G01 Signal Voltage Between (39), (40) – (37), (38) Constant power supply 20 – 30 V 2 Defective GPS aTurn starting switch ON and carry out troubleshooting. LED (2) Normal state LED-A2 Lighted up 3 Defective starting switch ACC signal and alternator R signal aStart engine and carry out troubleshooting. LED (6) Normal state LED-C1 Lighted up aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting.

G01 Signal Voltage Between (36) – (37), (38) Starting switch ACC 20 – 30 V Between (28) – (37), (38) Alternator R 20 – 30 V 4 Defective starting switch C signal aTurn starting switch ON and carry out troubleshooting. LED (8) Normal state LED-C3 Lighted up aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. G01 Signal Voltage Between (10) – (9) S-NET 6 – 9 V Between (27) – (37), (38) Starting switch C Max. 1 V 5 Defective state of CAN connection aTurn starting switch ON and carry out troubleshooting. LED (9) Normal state LED-C4 Lighted up aPrepare with starting switch OFF and carry out troubleshooting.

G01 Signal Resistance Between (7) – (8) CAN 40 – 80 z