Kaiyi BR380JG-1E0 — H-1 THE SPEED OR POWER OF THE WHOLE WORK EQUIPMENT AND TRAVEL IS LOW

40 Troubleshooting SEN02306-01 Note 1: Disconnect the hydraulic hose and piping (travel main circuit) and install adapters to block the ends. BR380JG-1E0 9 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 6 Defective adjustment or malfunction of LS valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Oil pressure to be measured Ratio of oil pressure Turn all work equipment switches OFF Turn all work equipment switches ON (with no load) Pump discharge pressure Almost same 1 LS valve output pressure Approx.

3/5 If the oil pressure does not become normal after adjustment, the LS valve may have a malfunction or a defect in it. Check the LS valve directly. 7 Malfunction of servo piston The servo piston may have malfunction. Check it directly. 8 Defective piston pump If all the results of the above checks are normal, the cause may be lowering of performance, malfunction, or internal defect of the piston pump.