Kaiyi BR380JG-1E0 — H-5 FINE CONTROL PERFORMANCE OR RESPONSE IS LOW

SEN02306-01 40 Troubleshooting H-5 Fine control performance or response is low 1 12 BR380JG-1E0 Trouble • Fine control performance or response is low. Relative information • Carry out troubleshooting in the WORK mode. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of LS-EPC valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Mode Travel speed Travel lever LS-EPC output pressure Travel High speed Neutral position Approx. 0.39 MPa {Approx. 4 kg/cm2} Medium or Low speed Neutral position Approx. 2.34 MPa {Approx.

23.9 kg/cm2} 2 Clogging of LS circuit orifice The LS circuit orifice may be clogged. Check it directly. 3 Defective adjustment or malfunction of LS valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Oil pressure to be measured Ratio of oil pressure Turn all work equipment switches OFF Turn all work equipment switches ON (with no load) Pump discharge pressure Almost same 1 LS valve output pressure Approx. 3/5 If the oil pressure does not become normal after adjustment, the LS valve may have a malfunction or a defect in it. Check the LS valve directly. 4 Malfunction of servo piston The servo piston may have a malfunction. Check it directly.