Kaiyi BR380JG-1E0 — H-6 THE CONVEYOR DOES NOT OPERATE

40 Troubleshooting SEN02306-01 H-6 The conveyor does not operate 1 BR380JG-1E0 13 Trouble • The conveyor does not operate. Relative information • Carry out the following troubleshooting when the travel system and other work equipment are nor- mal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of acces- sory EPC valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. aCarry out troubleshooting in the WORK mode. Operation EPC valve output pressure Turn conveyor switch ON Min. 2.5 MPa {Min.

26 kg/cm2} 2 Malfunction of acces- sory control valve (spool) The accessory control valve spool may have a malfunction. Check it directly. 3 Malfunction of con- veyor rotation solenoid valve The conveyor rotation solenoid valve may have a malfunction. Check it directly. 4 1) Disconnection or short circuit in con- veyor-ON/OFF switch system 2) Disconnection or short circuit in accessory EPC valve system 3) Short circuit in con- veyor forward relay system 4) Disconnection in conveyor forward relay system 1) Carry out troubleshooting according to failure codes [7RC1KB] and [7RC2KA]. 2) Carry out troubleshooting according to failure codes [7RFLKB] and [7RFLKY].

3) Carry out troubleshooting according to failure codes [7RFHKB] and [7RFHKY]. 4) The conveyor relay system may have a disconnection. Check it directly.