Kaiyi BR380JG-1E0 — H-10 THE FEEDER DOES NOT OPERATE

SEN02306-01 40 Troubleshooting H-9 The speed or power of crusher is low 1 H-10 The feeder does not operate 1 16 BR380JG-1E0 Trouble • The speed or power of crusher is low. Relative information • Carry out the following troubleshooting when the travel speed is normal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of LS-EPC valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Operation LS-EPC output pressure Turn crusher switch ON Approx. 2.34 ± 0.15 MPa {Approx.

23.9 ± 1.5 kg/cm2} 2 Malfunction of crusher control valve (spool) The crusher control valve spool may have a malfunction. Check it directly. 3 Malfunction of pressure compensation valve or pressure compensa- tion piston The pressure compensation valve or pressure compensation piston of the control valve may have a malfunction. Check them directly. 4 Disconnection in crusher EPC valve sys- tem (Forward or reverse) Carry out troubleshooting according to failure codes [7RF2KA] and [7RF3KA].

5 Defective crusher motor Pulley Rotation direction Crusher speed (Maximum speed) Standard Normal rotation 280 – 380 rpm Reverse rotation 224 – 336 rpm Small (torque up) Normal rotation 246 – 334 rpm Reverse rotation 196 – 295 rpm Trouble • The feeder does not operate. Relative information • Carry out the following troubleshooting when the travel system and other work equipment are nor- mal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of feeder EPC valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. aCarry out troubleshooting in the WORK mode.

Operation EPC valve output pressure Set the feeder speed to the maximum rotation speed Min. 2.2 MPa {Min. 22 kg/cm2} 2 Malfunction of feeder control valve (spool) The feeder control valve spool may have a malfunction. Check it directly. 3 1) Disconnection or short circuit in feeder-ON/OFF switch system 2) Disconnection or short circuit in feeder forward EPC valve system 1) Carry out troubleshooting according to failure codes [7RC5KB] and [7REPKA]. 2) Carry out troubleshooting according to failure codes [7RF4KA], [7RF4KB], [7RF4KY].