40 Troubleshooting SEN02306-01 H-11 The feeder does not feed smoothly (Vibration frequency is low) 1 H-12 The magnetic separator does not operate 1 BR380JG-1E0 17 Trouble • The feeder does not feed smoothly (Vibration frequency is low). Relative information • Carry out the following troubleshooting when the travel speed is normal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of LS-EPC valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Operation LS-EPC output pressure Turn feeder switch ON Approx. 2.34 MPa {Approx.
23.9 kg/cm2} 2 Malfunction of feeder control valve (spool) The feeder control valve spool may have a malfunction. Check it directly. 3 Malfunction of pressure compensation valve or pressure compensa- tion piston The pressure compensation valve or pressure compensation piston of the control valve may have a malfunction. Check them directly. 4 Disconnection in feeder EPC valve sys- tem Carry out troubleshooting according to failure code [7RF4KA]. 5 Defective operation of safety valve and suc- tion valve for feeder The safety valve and suction valve for control valve feeder may be defec- tive. Check it directly. 6 Defective feeder motor Feeder vibration frequency (Maximum vibration):
1,000 – 1,100 cpm Trouble • The magnetic separator does not operate. Relative information • Carry out the following troubleshooting when the travel system and other work equipment are nor- mal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of mag- netic separator sole- noid valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. aCarry out troubleshooting in the WORK mode.
Operation Solenoid valve output pressure Turn magnetic separator switch ON 2.83 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of mag- netic separator control valve (spool) The magnetic separator control valve spool may have a malfunction. Check it directly. 3 1) Disconnection or short circuit in mag- netic separator-ON/ OFF switch system 2) Disconnection or short circuit in mag- netic separator sole- noid valve system 1) Carry out troubleshooting according to failure codes [7RE8KB] and [7RE9KA]. 2) Carry out troubleshooting according to failure codes [7RFCKA], [7RFCKB], [7RFCKY].