Kaiyi BR380JG-1E0 — H-14 THE SIDE CONVEYOR DOES NOT OPERATE

SEN02306-01 40 Troubleshooting H-13 The speed of magnetic separator belt is low 1 H-14 The side conveyor does not operate 1 18 BR380JG-1E0 Trouble • The speed of magnetic separator belt is low. Relative information • Carry out the travel speed is normal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of LS-EPC valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. Operation LS-EPC output pressure Turn magnetic separator switch ON Approx. 2.34 MPa {Approx.

23.9 kg/cm2} 2 Malfunction of mag- netic separator control valve (spool) The magnetic separator control valve spool may have a malfunction. Check it directly. 3 Malfunction of pressure compensation valve or pressure compensa- tion piston The pressure compensation valve or pressure compensation piston of the control valve may have a malfunction. Check them directly. 4 Malfunction of mag- netic separator safety valve and suction valve The magnetic separator safety valve and suction valve of the control valve may have a malfunction. Check it directly. 5 Defective magnetic separator motor Magnetic separator belt speed: 66 – 108 m/min Trouble • The side conveyor does not operate.

Relative information • Carry out the following troubleshooting when the travel system and other work equipment are nor- mal. • Muck discharge conveyor does not work when it is folded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of side conveyor solenoid valve aPrepare with engine stopped, then run engine at high idle and carry out troubleshooting. aCarry out troubleshooting in the WORK mode. Operation Solenoid valve output pressure Turn side conveyor switch ON 2.83 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of side conveyor control valve (spool) The side conveyor control valve spool may have a malfunction.

Check it directly. 3 Malfunction of side conveyor proximity switch The side conveyor proximity switch may have a malfunction. Check it directly. 4 1) Short circuit, discon- nection, or defective contact in side con- veyor-ON/OFF switch system 2) Disconnection or short circuit in side conveyor solenoid system 1) Carry out troubleshooting according to failure codes [7RE6KB] and [7RE7KA]. 2) Carry out troubleshooting according to failure codes [7RFBKZ] and [7RFBKB].